NIST Traceable Multi-Gas Mixture (SO2/NO/CO in N2) 10L Aluminum Cylinder EPA Protocol Standard Calibration Gas
- Overview
- Inquiry
- Related Products
About Product
Highlight







About Us
FAQs
What is the lead time for custom 99.9999% (6N) purity mixtures
How do you guarantee the concentration accuracy of the CF4/O2 mixture
Is this mixture stable given it contains both Hydrogen H2and Oxygen O2
What type of cylinder and valve are used for this semiconductor gas
What are the storage requirements for this gas mixture
Do you provide worldwide shipping for hazardous gases
AGEM presents the NIST Traceable Multi-Gas Mixture (SO2/NO/CO in N2) in a 10L Aluminum Cylinder EPA Protocol Standard Calibration Gas designed for high-precision instrument calibration, environmental monitoring compliance, and laboratory quality assurance. This NIST traceable calibration gas solution is engineered to meet strict regulatory and performance standards. The synergy of the multi-gas EPA protocol formulation with precise concentration control and the convenient 10L aluminum cylinder calibration format ensures reliable, repeatable results across field instruments, laboratory analyzers, and mobile monitoring systems.
Product Overview and Purpose
The AGEM NIST traceable calibration gas offering is a multi-gas EPA protocol standard intended for calibration of ambient air monitoring stations, continuous emissions monitoring systems (CEMS), portable analyzers, and research instrumentation. This NIST traceable calibration gas is a premium SO2 NO CO mixture in N2, supplied in a 10L aluminum cylinder calibration configuration to balance portability and adequate gas volume for repeated calibrations and verification checks. The multi-gas EPA protocol composition ensures simultaneous evaluation of sulfur dioxide, nitric oxide, and carbon monoxide response characteristics in analyzers, enabling efficient multi-point and single-point calibration workflows using a single calibration gas source.
Key Features
- NIST traceability and documentation: Each bottle of NIST traceable calibration gas is supplied with full documentation and traceability, enabling instrument users to demonstrate compliance with regulatory requirements. This NIST traceable calibration gas comes with certification and detailed concentration verification reports, ensuring traceability to national standards.
- Multi-gas EPA protocol composition: The product is formulated as a multi-gas EPA protocol standard to match EPA performance and QA/QC requirements. The SO2 NO CO mixture is specifically blended to reflect realistic monitoring conditions and to support EPA protocol checks and field audits.
- 10L aluminum cylinder calibration format: The 10L aluminum cylinder calibration size is optimized for field technicians and laboratory staff who require a compact, lightweight solution that still provides sufficient volume for multiple calibrations. The 10L aluminum cylinder calibration packaging simplifies storage, transportation, and handling while maintaining gas integrity.
- High chemical stability and purity: The SO2 NO CO mixture in N2 is blended using stringent controls to reduce adsorption and interaction inside the cylinder. Chemical stability ensures concentration consistency over the cylinder’s useful life and supports accurate calibration of analyzers.
- Precision concentration control: AGEM applies advanced blending technologies and calibration-grade standards to produce reproducible concentrations for each batch of NIST traceable calibration gas. The precision control enables accurate instrument linearity checks and multi-point calibrations using the SO2 NO CO mixture.
- Compatibility with a wide range of instruments: This multi-gas EPA protocol blend is compatible with Chemiluminescence NO analyzers, non-dispersive infrared CO instruments, UV fluorescence SO2 monitors, and other common gas detection systems used in environmental monitoring and emissions testing.
- Safety and convenience: The 10L aluminum cylinder calibration vessel is manufactured to high safety and quality standards, featuring durable construction that minimizes leak potential while remaining easy to handle for field use.
Applications
- Ambient air monitoring stations: The NIST traceable calibration gas is ideally used for routine calibration and performance checks of ambient air monitoring instruments that measure SO2, NO, and CO. The multi-gas EPA protocol composition expedites calibration procedures and supports compliance with regulatory monitoring frameworks.
- Continuous emissions monitoring systems (CEMS): Power plants, industrial facilities, and combustion sources can rely on this multi-gas EPA protocol blend for CEMS calibration and linearity checks. The multi-component SO2 NO CO mixture enables verification of cross-sensitivities and combined instrument response under representative gas conditions.
- Portable and handheld analyzers: Field technicians benefit from the 10L aluminum cylinder calibration convenience for on-site instrument verification. The compact cylinder format makes the NIST traceable calibration gas practical for mobile environmental surveys and emergency response teams.
- Research and development labs: Analytical laboratories conducting atmospheric chemistry research or instrument development can use the SO2 NO CO mixture in N2 for method validation, instrument comparison studies, and experimental calibration needs.
- Quality assurance and proficiency testing: The multi-gas EPA protocol standard is suitable for internal QA programs and inter-laboratory proficiency testing where traceable standards and accurate documentation are required.
Innovation and Technical Advantages
- Advanced blending and validation: AGEM’s R&D and manufacturing processes incorporate modern gas blending systems and rigorous validation protocols. Each batch of NIST traceable calibration gas is verified using precision analytical techniques to confirm target concentrations for the SO2 NO CO mixture, ensuring consistency across production runs.
- Low adsorption cylinder surface treatment: To preserve the integrity of the SO2 NO CO mixture over time, AGEM employs specialized surface treatments and cylinder preparation procedures that reduce adsorptive losses and interactions. This treatment enhances the long-term stability of the mixture in the 10L aluminum cylinder calibration format.
- Tight specification tolerances: The product is produced to narrow uncertainty margins suitable for EPA protocol checks and laboratory calibration needs. The precise concentration control of this NIST traceable calibration gas supports confident instrument calibration for regulatory and research applications.
- Comprehensive calibration documentation: AGEM supplies calibration certificates and traceability chains for the NIST traceable calibration gas, including measurement uncertainty, cylinder identification, and production batch data. These records simplify regulatory audits and laboratory record-keeping.
- Global support and logistics: AGEM’s regional service capability ensures timely supply and replacement across multiple markets. The choice of a 10L aluminum cylinder calibration format aids in international shipping considerations while maintaining product safety and compliance.
Quality Assurance and Compliance
AGEM maintains strict quality assurance procedures throughout the blending and dispensing process. Each cylinder of NIST traceable calibration gas undergoes inspection and analytical verification prior to dispatch. The multi-gas EPA protocol standard is produced in compliance with relevant safety and handling standards for calibration gases. Analytical traceability to NIST reference materials and documentation ensures end users can meet regulatory and accreditation requirements.
Technical Specifications Summary
- Composition: SO2/NO/CO in N2 - customizable concentrations available
- Cylinder: 10L aluminum cylinder calibration pack, DOT and international transport compliant
- Traceability: NIST traceable calibration gas certificate with measurement uncertainty and batch data
- Use: Multi-gas EPA protocol calibration, ambient and emissions monitoring, laboratory QA/QC
Ordering and Custom Options
AGEM offers flexible concentration ranges for the SO2 NO CO mixture to match specific instrument ranges and calibration procedures. Customers can request single-point or multi-point standards, different concentration levels, and tailored documentation to support unique quality systems. The 10L aluminum cylinder calibration is available with compatible regulators and fittings upon request.
Why Choose AGEM
AGEM’s long-standing expertise in specialty, electronic, bulk, and calibration gases ensures reliable product performance and knowledgeable technical support. The NIST traceable calibration gas is produced under controlled manufacturing conditions with comprehensive documentation to support regulatory compliance. Choosing AGEM for your NIST traceable calibration gas needs means selecting a partner that balances innovation, quality, and service
AGEM’s NIST Traceable Multi-Gas Mixture (SO2/NO/CO in N2) in a 10L Aluminum Cylinder EPA Protocol Standard Calibration Gas provides a robust, traceable, and convenient calibration solution for environmental monitoring, emissions testing, and laboratory applications. With precise concentration control, multi-gas EPA protocol relevance, and full NIST traceability, this 10L aluminum cylinder calibration product supports rigorous QA/QC regimes and simplifies calibration workflows for a broad array of instrument platforms.
EN
AR
CS
DA
NL
FI
FR
DE
EL
IT
JA
KO
NO
PL
PT
RO
RU
ES
TL
ID
SK
SL
UK
VI
TH
TR
AF
MS
SW
GA
CY
BE
KA
LO
LA
MI
MR
MN
NE
UZ