All Categories

Calibration Gas

Home >  Products >  Mixture Gases >  Calibration Gas

NIST Traceable Multi-Gas Mixture (SO2/NO/CO in N2) 10L Aluminum Cylinder EPA Protocol Standard Calibration Gas

  • Overview
  • Inquiry
  • Related Products

About Product

Highlight

Our premium Calibration Gas Mixtures for Exhaust Gas Monitoring are engineered to provide the ultimate accuracy for emission testing and environmental compliance. Utilizing advanced gravimetric blending techniques, these mixtures precisely combine critical components such as Carbon Monoxide (CO), Carbon Dioxide (CO2), Hydrocarbons (HC), Nitrogen Oxides (NO), and Oxygen (O2) to meet stringent regulatory requirements. To ensure the integrity of reactive gases, each cylinder undergoes a proprietary internal passivation process that prevents component absorption and maintains chemical stability for an extended shelf life of 12 to 24 months. Every batch is rigorously analyzed and supplied with a traceable Certificate of Analysis (CoA), ensuring that your data aligns with international standards such as NIST. Whether used for automotive inspection stations, Continuous Emission Monitoring Systems (CEMS) in industrial stacks, or environmental research, these high-purity standard gases deliver exceptional repeatability and rapid sensor response. By minimizing measurement drift and false readings, our calibration gases empower you to maintain seamless operational compliance and precise control over environmental impact
Other product imagesOther product imagesOther product imagesOther product imagesProduct dimensionsScene imageScene imageScene image  

About Us

AGEM was established in 2008 as a multinational professional manufacturer and service provider of gas equipment, headquartered in Taiwan, China. With 16 years of dedicated industry expertise, its global footprint, superior manufacturing craftsmanship, and comprehensive product portfolio have solidified its status as a benchmark enterprise in the gas equipment sector. The company adheres to a globalization development strategy, establishing modern production bases in Chinese Mainland, Taiwan, China, and India, forming a production and service network that covers Asia and extends globally. Each base is equipped with intelligent production lines and precision testing equipment, enabling full-process control from raw material processing to finished product delivery. With annual production capacity consistently ranking among industry leaders, the company can swiftly respond to the diverse needs of global clients. The core business focuses on gas-related core equipment, encompassing a full range of products including various industrial gases, specialized gas valves, high-pressure cylinders, lightweight aluminum cylinders, and high-precision pressure reducers. These products are widely applied in critical sectors such as chemicals, electronics, healthcare, and energy. Leveraging profound technical expertise, the products have obtained ISO9001 Quality Management System certification and multiple authoritative international certifications, including ASME certification for high-pressure equipment, CE-PED certification for EU market access, and IECEx explosion-proof certification for global application. Key performance indicators such as sealing performance, pressure resistance, and safety protection have achieved internationally advanced levels. The company consistently prioritizes technological innovation as its core competitive strength, assembling an international R&D team and continuously investing in technological breakthroughs
Company overview  Competitive advantages  Factory profile  Factory profile  Customization capabilities

FAQs

What is the lead time for custom 99.9999% (6N) purity mixtures

For ultra-high purity (UHP) gases like CF4/O2, the typical lead time is 10-15 working days. This includes precision blending and multi-stage stability testing to ensure the 6N grade purity and concentration accuracy

How do you guarantee the concentration accuracy of the CF4/O2 mixture

We use the gravimetric method (high-precision weighing) during filling, which is the most accurate blending technique. Each cylinder is analyzed via Gas Chromatography (GC) and comes with a Certificate of Analysis (COA) traceable to NIST or national standards

Is this mixture stable given it contains both Hydrogen H2and Oxygen O2

Yes. We strictly follow safety blending protocols where the concentration of flammable and oxidative components is kept within safe limits or balanced with Argon (Ar) to ensure chemical stability and prevent any hazardous reactions inside the cylinder

What type of cylinder and valve are used for this semiconductor gas

We use internally passivated aluminum alloy cylinders or polished stainless steel cylinders to prevent surface adsorption. For 6N grade gases, we typically equip them with DISS (Digital Intelligent Scheduling System) 660 or SS 316L stainless steel valves to ensure zero leakage and prevent contamination

What are the storage requirements for this gas mixture

Cylinders should be stored in a cool, dry, and well-ventilated area, away from direct sunlight and heat sources (temperature < 50° C Ensure the cylinders are secured upright to prevent falling

Do you provide worldwide shipping for hazardous gases

Yes, we specialize in Class 2 hazardous goods logistics. We provide full documentation including MSDS (Material Safety Data Sheet), UN-certified packaging, and DG (Dangerous Goods) declarations for sea or air freight



AGEM presents the NIST Traceable Multi-Gas Mixture (SO2/NO/CO in N2) in a 10L Aluminum Cylinder EPA Protocol Standard Calibration Gas solution designed for laboratories, environmental monitoring agencies, industrial process control, and instrument manufacturers requiring precise, reliable reference standards. This NIST traceable calibration gas product delivers exceptional performance and traceability for emissions monitoring, ambient air quality measurements, and regulatory compliance testing. By choosing AGEM’s NIST traceable calibration gas, users obtain an EPA protocol standard gas that supports accurate instrument calibration, verification, and performance checks across a wide range of applications.

 

Product Overview and Key Features

The AGEM NIST traceable calibration gas is a multi-component SO2 NO CO mixture formulated in high-purity nitrogen and supplied in a 10L aluminum cylinder calibration configuration. This SO2 NO CO mixture is prepared under stringent quality control to meet NIST traceable calibration gas requirements and to align with EPA protocol standard gas specifications for ambient and stationary source monitoring. The NIST traceable calibration gas is available in certified concentrations appropriate for instrument span, zero checks, and multi-point calibration routines. The compact 10L aluminum cylinder calibration package ensures portability and convenience for field calibration tasks and mobile laboratories, while providing the stability and safety inherent to aluminum cylinders.

 

Traceability, Certification, and Compliance

AGEM’s NIST traceable calibration gas is accompanied by certificates of analysis and documentation that establish measurement traceability to NIST standards. This traceability ensures that the SO2 NO CO mixture results are credible and reproducible across different laboratories and monitoring sites. The EPA protocol standard gas designation signals that the formulation and certification procedures conform to EPA guidelines for quality assurance and performance evaluation of ambient air monitoring instruments. Users relying on EPA protocol standard gas for compliance testing and regulatory submissions can have confidence in the integrity of the AGEM NIST traceable calibration gas.

 

Applications and Use Cases

The NIST traceable calibration gas is tailored for a variety of critical applications, including:

- Ambient air quality monitoring networks requiring regular calibration using NIST traceable calibration gas.

- Stack emissions testing where EPA protocol standard gas is required to validate continuous emissions monitoring systems (CEMS).

- Portable gas analyzers and field instruments that benefit from the convenience of a 10L aluminum cylinder calibration supply.

- Research laboratories and instrument manufacturers performing instrument development, performance characterization, and inter-laboratory comparisons using SO2 NO CO mixture reference standards.

- Environmental consulting firms conducting field audits and compliance assessments using EPA protocol standard gas.

 

Technical Advantages and Innovation

AGEM’s NIST traceable calibration gas demonstrates several technical advantages. First, the precise SO2 NO CO mixture formulation is created using high-purity base gases and advanced blending techniques developed by AGEM’s R&D team. This rigorous manufacturing process yields stable concentrations with minimal drift, enhancing the reliability of calibration routines. Second, the use of a 10L aluminum cylinder calibration vessel offers benefits in terms of weight reduction, corrosion resistance, and thermal stability compared with steel alternatives. Third, AGEM employs robust quality control, including regular inspections and testing, to ensure each EPA protocol standard gas cylinder meets documented specifications and maintains NIST traceable calibration gas status.

 

Innovation is also evident in AGEM’s documentation and support services. Every NIST traceable calibration gas shipment includes a certificate of analysis and detailed information on uncertainty, expiration recommendations, and handling instructions specific to the SO2 NO CO mixture. AGEM’s approach to blending and certification minimizes cross-contamination risks and enhances homogeneity, enabling end users to rely on consistent EPA protocol standard gas performance for critical calibration tasks.

 

Performance Characteristics

AGEM’s SO2 NO CO mixture in N2 is available in multiple concentration ranges to match instrument sensitivity and operational requirements. The NIST traceable calibration gas showcases low uncertainty values derived from comprehensive analysis and calibration chains traceable to NIST reference standards. Cylinder stability is optimized through careful selection of cylinder materials and passivation techniques, while the 10L aluminum cylinder calibration format supports rapid deployment and convenient change-out intervals for field technicians. The EPA protocol standard gas designation further affirms suitability for use in regulatory-quality calibration and performance audits.

 

Safety, Handling, and Storage

Safety is central to AGEM’s product design and distribution practices. The 10L aluminum cylinder calibration format is engineered to meet industry safety standards for pressurized gas containment and transport. AGEM provides guidance on safe handling procedures, storage conditions, and cylinder return or recycling programs to ensure compliance with local regulations. The NIST traceable calibration gas documentation includes recommended purge procedures and connector compatibility notes to minimize the risk of contamination when the SO2 NO CO mixture is introduced to analyzers and manifolds.

 

Quality Assurance and Support

AGEM’s manufacturing and QA processes are tailored to deliver a consistent NIST traceable calibration gas experience. The SO2 NO CO mixture is produced in a controlled environment with validated blending systems and analytical verification. AGEM’s QA team conducts periodic audits, stability checks, and inter-laboratory comparisons to maintain the integrity of EPA protocol standard gas products. In addition to certifications, AGEM offers technical support for gas selection, calibration planning, and troubleshooting to help customers integrate NIST traceable calibration gas supplies into their quality systems.

 

Why Choose AGEM’s NIST Traceable Multi-Gas Mixture

Choosing AGEM for NIST traceable calibration gas needs ensures access to a product backed by deep expertise in specialty and calibration gases. AGEM’s reputation for rigorous quality control, global service coverage, and research-driven innovations makes the SO2 NO CO mixture a dependable choice for agencies and businesses that require EPA protocol standard gas reliability. The 10L aluminum cylinder calibration format provides a practical balance between portability and usable volume for frequent calibrations and field activities.

 

Ordering, Customization, and Delivery

AGEM offers flexible ordering options and can customize the SO2 NO CO mixture concentrations to meet specific instrument calibration protocols or regulatory requirements. Customers can request specific concentration ranges, cylinder fittings, and certification levels to match their operational needs for NIST traceable calibration gas. AGEM supports global delivery and can provide logistic solutions tailored to the handling and shipping of EPA protocol standard gas cylinders.

 

AGEM’s NIST Traceable Multi-Gas Mixture (SO2/NO/CO in N2) in a 10L aluminum cylinder calibration package combines traceability, regulatory compliance, and technical innovation to meet the rigorous demands of ambient monitoring, emissions testing, and instrument calibration. With comprehensive certification, robust quality assurance, and flexible support services, AGEM’s EPA protocol standard gas offering helps ensure accurate, repeatable calibration results for critical environmental and industrial measurements.

GET IN TOUCH