All Categories

Calibration Gas

Home >  Products >  Mixture Gases >  Calibration Gas

8L Calibration Gas Mixture NO CO SO2 O2 H2S in N2 Balance Standard Mixture Gas for Flue Gas Analyzer Environmental Monitoring

  • Overview
  • Inquiry
  • Related Products
PRODUCT HIGHLIGHTS

      1. The Core Product

  • Our premium Calibration Gas Mixtures for Exhaust Gas Monitoring are engineered to provide the ultimate accuracy for emission testing and environmental compliance. Utilizing advanced gravimetric blending techniques, these mixtures precisely combine critical components such as Carbon Monoxide (CO), Carbon Dioxide (CO2), Hydrocarbons (HC), Nitrogen Oxides (NO), and Oxygen (O2) to meet stringent regulatory requirements


    2. Stability & Tech

  • To ensure the integrity of reactive gases, each cylinder undergoes a proprietary internal passivation process that prevents component absorption and maintains chemical stability for an extended shelf life of 12 to 24 months


    3. Quality & Application

  • Every batch is rigorously analyzed and supplied with a traceable Certificate of Analysis (CoA), ensuring that your data aligns with international standards such as NIST. Whether used for automotive inspection stations, Continuous Emission Monitoring Systems (CEMS) in industrial stacks, or environmental research, these high-purity standard gases deliver exceptional repeatability and rapid sensor response


    4. Conclusion

  • By minimizing measurement drift and false readings, our calibration gases empower you to maintain seamless operational compliance and precise control over environmental impact


CALIBRATION GAS PARAMETERS
image-left
image-right
DETAIL SHOT
image
image
image
OTHER PRODUCT IMAGES
image
image
image
image
ABOUT THE SUPPLIER

AGEM was established in 2008 as a multinational professional manufacturer and service provider of gas equipment, headquartered in Taiwan, China. With 16 years of dedicated industry expertise, its global footprint, superior manufacturing craftsmanship, and comprehensive product portfolio have solidified its status as a benchmark enterprise in the gas equipment sector. The company adheres to a globalization development strategy, establishing modern production bases in Chinese Mainland, Taiwan, China, and India, forming a production and service network that covers Asia and extends globally. Each base is equipped with intelligent production lines and precision testing equipment, enabling full-process control from raw material processing to finished product delivery. With annual production capacity consistently ranking among industry leaders, the company can swiftly respond to the diverse needs of global clients. The core business focuses on gas-related core equipment, encompassing a full range of products including various industrial gases, specialized gas valves, high-pressure cylinders, lightweight aluminum cylinders, and high-precision pressure reducers. These products are widely applied in critical sectors such as chemicals, electronics, healthcare, and energy. Leveraging profound technical expertise, the products have obtained ISO9001 Quality Management System certification and multiple authoritative international certifications, including ASME certification for high-pressure equipment, CE-PED certification for EU market access, and IECEx explosion-proof certification for global application. Key performance indicators such as sealing performance, pressure resistance, and safety protection have achieved internationally advanced levels. The company consistently prioritizes technological innovation as its core competitive strength, assembling an international R&D team and continuously investing in technological breakthroughs


COMPANY OVERVIEW
image
COMPETITIVE ADVANTAGES
image
FACTORY PROFILE
image
image
CUSTOMIZATION CAPABILITIES
image
FAQs
Q1: What gas components can you provide

A: We can provide a wide range of balance gases and target gas combinations, including but not limited to N2, H2, He, CO2, CO, CH4, and O2. We are able to accurately prepare various multi-component gas mixtures according to your specific requirements, whether in ppm levels or percentage concentrations


Q2: Why use aluminum cylinders for calibration gases

A: Aluminum alloy cylinders (such as 2L / 8L / 10L / 20L) offer the following advantages:

*  High stability: The inner surface of aluminum cylinders has better passivation properties, which effectively prevents trace gases (especially reactive components) from reacting with the cylinder wall, ensuring long-term stability of the calibration concentration
*  Lightweight: Approximately 40% lighter than steel cylinders of the same specification, making them more convenient for on-site calibration work

*  Corrosion resistance: Suitable for storing high-purity gases and mildly corrosive gas mixtures


Q3: What is the shelf life of the calibration gases

A: Under normal conditions:

*  Non-reactive gas mixtures (such as N2 / CO2 / He mixtures) typically have a shelf life of 24 months
*  Gas mixtures containing reactive components (such as H2S, NO, or SO2) generally have a shelf life of 6–12 months

The specific expiration period will be indicated on the cylinder label and the Certificate of Analysis - COA


Q4: How do you ensure gas concentration accuracy

A: Every cylinder of calibration gas undergoes strict quality control before shipment:

*  Gravimetric preparation: Prepared using high-precision balances through the gravimetric method
*  Instrument analysis: Verified using Gas Chromatography (GC) or infrared analyzers
*  COA certificate: A Certificate of Analysis is provided with each shipment, listing the preparation value, analyzed value, and uncertainty

Q5: What are the compliance and trans

A: Certain specific components (such as some high-concentration gas mixtures) may fall under Dual-use Items regulations. We strictly comply with export control laws:

*  All cargo involving restricted components must be shipped within the validity period of the export permit.

*  Gas cylinders are classified as dangerous goods (Class 2.2 or 2.1) and must be packaged and transported in accordance with international regulations such as IMDG and IATA


Q6: What are the cylinder valve specifications

A: We can provide various valve connections according to different national and industrial standards, including:

*  CGA series - U.S. standard
*  BS series - British standard
*  DIN series - German standard
*  QF series - Chinese standard
Please confirm your regulator connection type before placing the order

AGEM presents the 8L Calibration Gas Mixture NO CO SO2 O2 H2S in N2 Balance: a precision-engineered, multi-component calibration mix designed for flue gas analyzer calibration and environmental monitoring gases applications. Specifically formulated to support accurate flue gas analyzer calibration and reliable environmental monitoring gases measurement, this 8L calibration gas mixture provides a stable trace gas standard mixture that meets the demanding requirements of industrial emissions monitoring, regulatory compliance, and laboratory quality assurance. As a product from AIR GAS ELECTRONIC MATERIALS (AGEM), this multi-component calibration mix leverages our decades-long expertise in specialty and calibration gases to deliver consistent, reproducible performance for critical testing and calibration workflows.

 

Product overview and intended applications

The AGEM 8L Calibration Gas Mixture NO CO SO2 O2 H2S in N2 Balance is a compact, transportable multi-component calibration mix tailored for flue gas analyzer calibration tasks. This trace gas standard mixture contains nitrogen as the balance gas and carefully controlled concentrations of nitric oxide (NO), carbon monoxide (CO), sulfur dioxide (SO2), oxygen (O2), and hydrogen sulfide (H2S). It is optimized for environmental monitoring gases programs, continuous emissions monitoring systems (CEMS) calibration, stack testing, and routine field verification of flue gas analyzer calibration. Whether used in stationary source testing, portable analyzers, or laboratory instrumental checks, this multi-component calibration mix ensures that flue gas analyzers and monitoring instruments produce trustworthy, defensible data for regulatory reporting and process control.

 

Key features and specifications

- Multi-component calibration mix: Combines NO, CO, SO2, O2, and H2S in a nitrogen balance to simulate typical flue gas constituents for thorough flue gas analyzer calibration and environmental monitoring gases verification.

- Compact 8L cylinder format: Small, lightweight, and convenient for field use, enabling technicians to carry a reliable trace gas standard mixture to remote sites for on-site flue gas analyzer calibration.

- High stability and low drift: Produced under stringent quality control procedures to ensure the multi-component calibration mix remains stable over its certified shelf life, reducing uncertainty in environmental monitoring gases measurements and extending useful service life between cylinder replacements.

- NIST-traceable standards (upon request): Calibration and certification options are available to link the trace gas standard mixture to national standards, strengthening measurement traceability for flue gas analyzer calibration and compliance testing.

- Flexible concentration ranges: AGEM provides tailored concentration levels of NO, CO, SO2, O2, and H2S to match analyzer span ranges and method requirements for environmental monitoring gases and flue gas analyzer calibration routines.

- Safety and compliance: Manufactured, labeled, and shipped in compliance with applicable transportation and hazardous materials regulations, enabling safe deployment of this multi-component calibration mix in field and laboratory environments.

 

Technical advantages and innovation

AGEM’s 8L calibration gas mixture reflects advanced production controls and RD-driven innovation in calibration gas formulation. Our proprietary blending technology and meticulous quality control processes minimize cross-interactions and adsorption effects between components, preserving the intended composition of the trace gas standard mixture throughout its service life. For technicians conducting flue gas analyzer calibration, this attention to detail translates into lower measurement uncertainty and more reliable instrument performance. The multi-component calibration mix approach allows end users to validate multi-species analyzers in a single cylinder exchange, reducing downtime and logistic complexity compared to single-component standards.

 

Additionally, AGEM’s calibration gases are produced in clean-room environments with high-purity base gases and precision blending lines. This reduces contaminant backgrounds that can bias environmental monitoring gases readings and ensures that the trace gas standard mixture performs predictably within the target analyzer detection ranges. Our research and development capabilities enable customization of the multi-component calibration mix to meet specific instrument models, analytical methods, or regulatory thresholds, providing a flexible solution for operators requiring tailored flue gas analyzer calibration.

 

Applications and benefits in environmental monitoring

This 8L Calibration Gas Mixture NO CO SO2 O2 H2S in N2 Balance is ideally suited for a variety of environmental monitoring gases tasks. Regulatory compliance: The multi-component calibration mix supports routine flue gas analyzer calibration required for compliance with emissions limits and reporting obligations. By using a trace gas standard mixture that reflects actual flue gas composition, facilities can produce more credible calibration results and strengthen audit defensibility. Field verification and portable analyzers: The compact cylinder is engineered for field service technicians who perform on-site flue gas analyzer calibration or quick checks on portable environmental monitoring gases instruments. Using a multi-component calibration mix reduces cylinder swaps, simplifies logistics, and accelerates verification procedures. Laboratory quality assurance: Calibration labs can use the trace gas standard mixture for method validation, inter-laboratory comparisons, and routine instrument performance checks, maintaining consistent standards across testing programs.

 

Why choose AGEM

AGEM’s reputation as a Taiwan-based gas manufacturing and RD company specializing in specialty, electronic, bulk, and calibration gases underpins the value of this multi-component calibration mix. We apply rigorous quality control processes, including regular inspections and testing, to ensure each cylinder meets published specifications. Our global distribution and RD support enable customers across six regions to access reliable calibration solutions for flue gas analyzer calibration and environmental monitoring gases. AGEM’s emphasis on product excellence and traceability helps laboratories, field teams, and industrial operations reduce measurement uncertainty and remain confident in their emissions data.

 

Use cases and practical guidance

- Routine CEMS span checks: Use the 8L Calibration Gas Mixture to perform regular span and zero checks on continuous emissions monitoring systems that measure NO, CO, SO2, O2, and H2S, streamlining flue gas analyzer calibration in one compact cylinder. - Stack testing and source measurement: Bring the multi-component calibration mix to stack test sites to verify analyzer performance before and after source measurements, ensuring accurate environmental monitoring gases reporting. - Portable analyzer audits: Field auditors can carry the 8L cylinder to validate portable flue gas analyzers and handheld instruments, leveraging the trace gas standard mixture for quick instrument checks. - Laboratory method validation: Analytical labs can employ the multi-component calibration mix as part of standard operating procedures for instrument calibration, supporting reproducible environmental monitoring gases data.

 

Quality assurance and certification

AGEM follows documented production protocols to maintain batch-to-batch consistency for this multi-component calibration mix. Calibration certificates and gas analysis documentation are available, with options for third-party or NIST-traceable certification to meet stringent quality requirements for flue gas analyzer calibration and environmental monitoring gases. Our post-production testing and stability assessments ensure the trace gas standard mixture delivers the stated concentrations throughout the cylinder’s shelf life. Customer support and customization AGEM’s RD team can advise on selecting concentration levels to match analyzer ranges, sampling systems, and regulatory needs. We offer cylinder exchange programs, custom cylinder labeling, and tailored certification packages to facilitate integration of the multi-component calibration mix into existing calibration workflows. Technical support includes guidance on proper cylinder handling, cylinder conditioning, and best practices for flue gas analyzer calibration using the trace gas standard mixture.

 

AGEM’s 8L Calibration Gas Mixture NO CO SO2 O2 H2S in N2 Balance is a compact, reliable multi-component calibration mix purpose-built for flue gas analyzer calibration and environmental monitoring gases applications. Backed by AGEM’s rigorous quality control, precision blending, and RD expertise, this trace gas standard mixture helps operators achieve accurate, traceable, and efficient calibration procedures for emissions monitoring, regulatory compliance, and laboratory quality assurance. Choose AGEM for a stable, validated multi-component calibration mix that simplifies flue gas analyzer calibration and supports robust environmental monitoring gases measurement programs.

 

GET IN TOUCH