2L 4L 8L 10L Calibration Gas for Exhaust Gas Monitoring Standard Mixture Gas SO2 H2S CH4 CO CO2 N2 Gas Mixture
- Overview
- Inquiry
- Related Products



Gas Element |
Concentration |
Relative Expanded Uncertainty |
||
O2 in N2 |
5~30 - 10-2mol/mol |
1% - k=3 |
||
CO, CO2, Proane, NO in N2 |
NO 100~499 - μmol/mol |
2% - k=2 |
||
propane 100~999 - μmol/mol |
1.5% - k=2 |
|||
CO 0.5%~0.99% |
||||
CO2 0.1%~0.99% |
||||
NO 500~5000 - μmol/mol |
1% - k=2 |
|||
Propane 1000~50000 - μmol/mol |
||||
CO 1%~10% |
||||
CO2 1%~15% |
||||
NO, CO2 in N2 |
NO 10~1×104 - μmol/mol |
2% - k=2 |
||
CO2 10~20×104 - μmol/mol |
||||
CO, CO2, Propane in N2 |
Propane10~5×104 - μmol/mol |
2%(k=2 |
||
CO 10~20×104 - μmol/mol |
||||
CO2 10~20×104 - μmol/mol |
||||
CO, CO2, Propane, NO, NO2 in N2 |
NO 10~1×104 - μmol/mol |
2%(k=2 |
||
propane 10~5×104 - μmol/mol |
||||
CO 10~20×104 - μmol/mol |
||||
CO2 10~20×104 - μmol/mol |
||||
NO2 10~1000 - μmol/mol |
||||
H2 in N2 |
0.1~80 - 10-2mol/mol |
1% - k=2 |
||
H2 in He |
30~50 - 10-2mol/mol |
1% - k=2 |
||
Propane in Air |
1~99.9 - μmol/mol |
2% - k=2 |
||
100~1×104 - μmol/mol |
1% - k=2 |
|||
CO in N2 |
5~499 - μmol/mol |
2% - k=2 |
||
500~5×104 - μmol/mol |
1% - k=2 |
|||
NO in N2 |
10~1×103 - μmol/mol |
2% - k=2 |
||
CO2 in N2 |
2~499 - μmol/mol |
2% - k=2 |
||
5~1×104 - μmol/mol |
1% - k=2 |
|||
NO2 in N2 |
10~1×103 - μmol/mol |
2% - k=2 |
||
CH4 in Air |
1~4999 - μmol/mol |
2% - k=2 |
||
5000~3×104 - μmol/mol |
1% - k=2 |
|||
ethane in Air |
>1.00 - μmol/mol |
2% - k=2 |
||
N20 in N2 |
>1.00 - μmol/mol |
2% - k=2 |




1. What is the MOQ
A: From one cylinder
2. What is the delivery time
A: 7–10 days EXW (Ex Works) after we receive the deposit. Once we book the air freight, we will be able to provide the exact delivery timeline to the customer's country.
3. How do you check the gas quality
A: First, our team prepares the cylinders (cleaning, drying, vacuuming, pumping, and purging before gas filling to ensure the inside of the cylinder is clean and dry). Second, we test the treated cylinders again to confirm that the interior remains clean and dry. Third, we analyze the gas after filling the cylinders and provide a COA (Certificate of Analysis).
4. Can all cylinders be recycled
A: Generally, the service life of seamless steel cylinders is over 20 years. Disposable cylinders, however, are strictly for single use.
5. Can we send empty cylinders back to China for refilling
A: Yes. Once the gas is used up, you can return the empty cylinders to us for refilling. Please inform us prior to shipment so we can arrange customs clearance for the cylinders in China.
6. Available Cylinder and Valve Standards
A: Cylinder Standards: DOT-3AA, ISO9809, GB5099, TC-3AAM, EN1964, KGS
Valve Standards: DISS, CGA, DIN, BS, AFNOR, JIS
7. Can I ship LCL with my other general cargo
A: Our products are classified as Class 2.2 Dangerous Goods (DG) and must be shipped accordingly. Shipping them as general cargo is illegal, so we must book DG transport with the carrier. If you have general cargo, it can be combined with this shipment, provided the entire load is shipped under DG standards



AGEM Calibration Gas Solutions for Exhaust Gas Monitoring: Precision 2L, 4L, 8L, and 10L Standard Mixtures
AGEM delivers reliable calibration gas mixtures tailored for exhaust gas monitoring and environmental compliance. Our 2L, 4L, 8L, and 10L calibration gas cylinders provide precise, stable, and certified gas calibration standards suitable for field calibration, lab verification, and routine instrument checks. AGEM calibration gas mixtures are engineered for gas calibration standards across a wide range of monitoring systems and analytical platforms, ensuring consistent performance and regulatory confidence.
Product Features and Composition
AGEM offers calibration gas mixtures containing SO2 H2S CH4 CO CO2 N2 in accurately controlled concentrations. Each calibration gas mixture is prepared under stringent quality control processes to deliver homogeneity and long-term stability. The AGEM 2L, 4L, 8L, and 10L cylinders are designed to meet diverse volume needs while maintaining identical gas calibration standards, enabling technicians to choose the optimal cylinder size without compromising mixture fidelity.
Key features:
- Certified gas calibration standards: Each cylinder is accompanied by a certificate detailing concentration values, uncertainty, and analysis methods for the calibration gas mixtures containing SO2 H2S CH4 CO CO2 N2.
- Range of concentrations: AGEM calibration gas mixtures can be supplied across a wide concentration range, allowing precise simulation of exhaust gas monitoring conditions for calibration of sensors and analyzers.
- Multiple cylinder sizes: Available in 2L, 4L, 8L, and 10L volumes to suit portable analyzers, fixed monitoring stations, and laboratory calibrations using calibration gas mixtures that match application requirements.
- Long-term stability and traceability: AGEM implements rigorous controls and periodic testing to ensure the calibration gas mixtures retain certified concentrations throughout the product lifetime, supporting accurate calibration against gas calibration standards.
- Compatibility and safety: Cylinders and valves are compatible with standard regulators and fittings used in exhaust gas monitoring, with clear labeling and safety documentation for all calibration gas mixtures.
Applications in Exhaust Gas Monitoring
AGEM calibration gas mixtures are specifically designed for exhaust gas monitoring applications. Proper calibration with certified calibration gas mixtures is essential for regulatory reporting, emissions control strategies, and environmental monitoring programs. AGEM supports operators, engineers, and laboratory personnel in achieving accurate measurement results by providing calibration gas mixtures optimized for target analytes: SO2 H2S CH4 CO CO2 N2.
Common application scenarios include:
- Industrial stack monitoring: Use AGEM calibration gas mixtures to calibrate and validate continuous emissions monitoring systems (CEMS) for SO2 H2S CH4 CO CO2 N2, ensuring compliance with local and international standards.
- Portable emission analysis: Technicians performing field calibrations can rely on AGEM 2L and 4L cylinders of calibration gas mixtures to perform quick instrument checks and zero/span adjustments on portable analyzers.
- Laboratory instrument verification: AGEM 8L and 10L calibration gas mixtures provide sufficient volume for extensive verification procedures, method validation, and round-robin testing in analytical laboratories.
- Leak detection and safety monitoring: Calibrating sensors for toxic and flammable gases using AGEM calibration gas mixtures improves detection accuracy for routine safety inspections and incident response.
Innovations and Technical Advantages
AGEM combines advanced R&D capabilities with meticulous manufacturing to deliver superior calibration gas mixtures. Our innovations focus on producing calibration gas mixtures that meet demanding performance criteria for exhaust gas monitoring.
Precision blending technology: AGEM employs high-precision mass flow controllers and gravimetric preparation methods to create calibration gas mixtures with minimal bias and reproducible results. The blending process ensures that SO2 H2S CH4 CO CO2 N2 are present at specified concentrations that conform to gas calibration standards.
Traceable certification and uncertainty management: Each AGEM calibration gas mixture is supported by traceable analytical methods and documentation of measurement uncertainty. The certificate for each cylinder provides the analytical basis and compliance with international best practices for calibration gas mixtures and gas calibration standards.
Custom mixture formulation: AGEM can formulate bespoke calibration gas mixtures tailored to unique exhaust gas monitoring needs. Whether customers require specific ratios of SO2 H2S CH4 CO CO2 N2 or need tailored concentration levels to match instrument ranges, AGEM can deliver custom gas calibration standards for both routine and specialized applications.
Robust quality assurance: AGEM integrates rigorous quality control checkpoints throughout production, including incoming material verification, in-process monitoring, and final analysis. Production records and routine reanalysis reinforce product integrity so that users can rely on AGEM calibration gas mixtures during critical calibrations and audits.
Global distribution and technical support: With operations serving six regions, AGEM provides timely delivery and local support. Our technical team assists customers with selection of the correct cylinder volume and gas calibration standards, troubleshooting, and best-practice guidance for exhaust gas monitoring using AGEM calibration gas mixtures.
Benefits to End Users
- Improved measurement accuracy: Regular calibration with AGEM calibration gas mixtures directly improves data quality and instrument performance for exhaust gas monitoring.
- Compliance assurance: Certified calibration gas mixtures support adherence to regulatory requirements and provide documentation for audits and reporting of emissions containing SO2 H2S CH4 CO CO2 N2.
- Cost-effective calibration programs: Multiple cylinder sizes and custom mixtures from AGEM allow organizations to optimize inventory and reduce waste while maintaining gas calibration standards.
- Streamlined operations: AGEM’s technical support and reliable supply chain reduce downtime for calibration, enabling continuous operation of monitoring systems.
Quality and Safety Commitments
As a Taiwan-based manufacturer and RD company, AIR GAS ELECTRONIC MATERIALS (AGEM) maintains stringent quality controls. AGEM’s production, testing, and certification processes ensure calibration gas mixtures meet the expectations of environmental monitoring professionals. Safety data sheets, handling instructions, and cylinder labeling accompany each shipment of calibration gas mixtures to promote safe and compliant use in exhaust gas monitoring contexts involving SO2 H2S CH4 CO CO2 N2.
Ordering and Customization
AGEM provides flexible ordering options for 2L, 4L, 8L, and 10L calibration gas mixtures. Customers can request standard formulations or specify bespoke concentrations and component combinations to match instrument ranges and regulatory test points. AGEM’s global network ensures responsive delivery and documentation of gas calibration standards to support calibration schedules and compliance programs.
AGEM’s 2L, 4L, 8L, and 10L calibration gas mixtures are engineered for precision, stability, and traceability for exhaust gas monitoring. With certified gas calibration standards, custom formulation capabilities, and robust quality assurance, AGEM supports accurate calibration of instruments measuring SO2 H2S CH4 CO CO2 N2. Trust AGEM to deliver calibration gas mixtures that uphold measurement integrity and regulatory compliance for environmental and industrial monitoring programs.
EN
AR
CS
DA
NL
FI
FR
DE
EL
IT
JA
KO
NO
PL
PT
RO
RU
ES
TL
ID
SK
SL
UK
VI
TH
TR
AF
MS
SW
GA
CY
BE
KA
LO
LA
MI
MR
MN
NE
UZ